Tuesday, March 24, 2015

Eight Methods teach you how to chose a good dental chair unit

Dental chair is one of the most indispensable basic medical equipment to dental clinic, directly relating to the dental treatment activities. The performance and quality of dental chair will directly affect the business and professional image of the detal clinic. Therefore, how to chose and purchase a good confident dental chair are becoming a cricial and important problems to Dental Clinic.
The dentist's chair of the full figure
Guangzhou Medsinglong Global Group Co., Lts will teach you the basic methods of choosing dental chair.

1. The price of dental chair becomes the primary consideration. How can we chose a high quality of dental chair but without spending too much?

First of all, if your bussiness is on a small-scale and budget won't be too much, the hydraulic controlled dental chair is recommened becasuse of its cheapest price but poor durability. So, If dental clinic bussiness is on regular-scale, electric dental chair is the primary choise.

Here comes the question, what is a pneumatic hydraulic type dental chair? Pneumatic hydraulic control dental chair refers to the film controlling the action of the hand piece, disc foot switch combining with a hydraulic pump and a hydraulic tube is the main characteristic of this dental chait, controlling chair movement with hydraulic. Compared with electronically controlle dental chair, the durability of pneumatic hydraulic type is poorer. Electric control type refers to the hand piece movement during treatment is controlled by electromagnetic valve, the main feature is the multifunctional pedal switch or electric control pedal switch, motor refers to the movement of the chair . The movement of Dental chair from European production is mainly controlled by motor. When the back of the chair seat is open, you can see a small electric motor. Therefore, if you business is on big-scale, you are recommended to choose this kind of dental chair, it is more durable but in a high price Atucally, now electric dental chair is chosen by more and more dental clinics as their main dental equipment.

2.Whether the configuration of dental chair suit for yourself is important after picking the right type. If you are an oral physicians, you can eliminate strong suction device as it is not necessary (if strong suction is not optional but standard parts). In fact, base on your own situation, it is enough to have one hand piece.

3: To tell the difference qulality betwen comprehensive dental therapy machine, you need to observed from the following aspects.
First, check the appearance of the machine, to see whether the shell junction is combining closely, it shows the poor quality if if the void is large. Second, check the surface of metal parts and machining accuracy, the metal parts here mainly refers to the spray gun and hand piece casing, the quality is poor if they are rough. Finally, open the shell to observe chair heart position: motor or pump.
MSL(Guangzhou Medsingong Global Group Co., Ltd) tell you how to choose a good dental chair with professional method.

4.The clean situation of used dental chair.
Some parts of dental chair is difficult to clean. Like the rubber cover of the lamp arm is in good apperency but full of smudginess, where bacteria would survive. Chair surface material can use disinfectant to disinfect (such as alcohol). Strong and weak suction devices can match the disposable straws and the straw can be withstand 135 degrees high temperature disinfection. Multifunctional pedal switch and non-inductive also need to be met the reqquirement of the health.

5.Dental chair after-sales service--dental chair maintenance.
Many doctors have found that less companies would responsible for after-sales service of dental chair after selling their peoducts. As a result, the unnecessary lost has been caused because the the dental chair cannot be repaired immediately. MSL(Guangzhou Medsingling Global Group Co.,Ltd) enjoy high reputation in the after-sales service of dental chair, Quality is our culture, with us your money in safe your business in safe your success is our super goal our honesty will touch your heart, warranty commitment and technical support are necessary for you. If you have any questions towards dental chair please do not hesitate to contact our professional technical engineers. Email address: cindy@medicalequipment-msl.com.

6.Every experienced engineers will be aware of the problem if the installation and debugging do not reach the designated position.So, when you are in the demand of buying dental chair, it necessary to cooperate with a good capability company, which will offer you with the complete installation manual, product dimensions and technical parameter etc.

7.It is important to have a dental chair operation training.
The dental chair in wrong order are due to installation and debugging without maching the designated position, as well as the improper operation of a doctor. Therefore, dental equipment company training is critical for the dentist.

8. The dental chair prices training include the following:
The usage and maintenance of hand piece.
The controlling of the chair.
The elimination of some common problems( the fuse, the light bulb, tube, etc.).
The daily maintenance of dental chair.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,X-ray machine,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.
Related Posts
The 6 installation and maintenance methods for the dental chair
The article comes from:Eight Methods teach you how to chose a good dental chair unit
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

Eight Methods teach you how to chose a good dental chair unit

Dental chair is one of the most indispensable basic medical equipment to dental clinic, directly relating to the dental treatment activities. The performance and quality of dental chair will directly affect the business and professional image of the detal clinic. Therefore, how to chose and purchase a good confident dental chair are becoming a cricial and important problems to Dental Clinic.
The dentist's chair of the full figure
Guangzhou Medsinglong Global Group Co., Lts will teach you the basic methods of choosing dental chair.

1. The price of dental chair becomes the primary consideration. How can we chose a high quality of dental chair but without spending too much?

First of all, if your bussiness is on a small-scale and budget won't be too much, the hydraulic controlled dental chair is recommened becasuse of its cheapest price but poor durability. So, If dental clinic bussiness is on regular-scale, electric dental chair is the primary choise.

Here comes the question, what is a pneumatic hydraulic type dental chair? Pneumatic hydraulic control dental chair refers to the film controlling the action of the hand piece, disc foot switch combining with a hydraulic pump and a hydraulic tube is the main characteristic of this dental chait, controlling chair movement with hydraulic. Compared with electronically controlle dental chair, the durability of pneumatic hydraulic type is poorer. Electric control type refers to the hand piece movement during treatment is controlled by electromagnetic valve, the main feature is the multifunctional pedal switch or electric control pedal switch, motor refers to the movement of the chair . The movement of Dental chair from European production is mainly controlled by motor. When the back of the chair seat is open, you can see a small electric motor. Therefore, if you business is on big-scale, you are recommended to choose this kind of dental chair, it is more durable but in a high price Atucally, now electric dental chair is chosen by more and more dental clinics as their main dental equipment.

2.Whether the configuration of dental chair suit for yourself is important after picking the right type. If you are an oral physicians, you can eliminate strong suction device as it is not necessary (if strong suction is not optional but standard parts). In fact, base on your own situation, it is enough to have one hand piece.

3: To tell the difference qulality betwen comprehensive dental therapy machine, you need to observed from the following aspects.
First, check the appearance of the machine, to see whether the shell junction is combining closely, it shows the poor quality if if the void is large. Second, check the surface of metal parts and machining accuracy, the metal parts here mainly refers to the spray gun and hand piece casing, the quality is poor if they are rough. Finally, open the shell to observe chair heart position: motor or pump.
MSL(Guangzhou Medsingong Global Group Co., Ltd) tell you how to choose a good dental chair with professional method.

4.The clean situation of used dental chair.
Some parts of dental chair is difficult to clean. Like the rubber cover of the lamp arm is in good apperency but full of smudginess, where bacteria would survive. Chair surface material can use disinfectant to disinfect (such as alcohol). Strong and weak suction devices can match the disposable straws and the straw can be withstand 135 degrees high temperature disinfection. Multifunctional pedal switch and non-inductive also need to be met the reqquirement of the health.

5.Dental chair after-sales service--dental chair maintenance.
Many doctors have found that less companies would responsible for after-sales service of dental chair after selling their peoducts. As a result, the unnecessary lost has been caused because the the dental chair cannot be repaired immediately. MSL(Guangzhou Medsingling Global Group Co.,Ltd) enjoy high reputation in the after-sales service of dental chair, Quality is our culture, with us your money in safe your business in safe your success is our super goal our honesty will touch your heart, warranty commitment and technical support are necessary for you. If you have any questions towards dental chair please do not hesitate to contact our professional technical engineers. Email address: cindy@medicalequipment-msl.com.

6.Every experienced engineers will be aware of the problem if the installation and debugging do not reach the designated position.So, when you are in the demand of buying dental chair, it necessary to cooperate with a good capability company, which will offer you with the complete installation manual, product dimensions and technical parameter etc.

7.It is important to have a dental chair operation training.
The dental chair in wrong order are due to installation and debugging without maching the designated position, as well as the improper operation of a doctor. Therefore, dental equipment company training is critical for the dentist.

8. The dental chair prices training include the following:
The usage and maintenance of hand piece.
The controlling of the chair.
The elimination of some common problems( the fuse, the light bulb, tube, etc.).
The daily maintenance of dental chair.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,X-ray machine,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.
Related Posts
The 6 installation and maintenance methods for the dental chair
The article comes from:Eight Methods teach you how to chose a good dental chair unit
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

Wednesday, March 18, 2015

The 6 installation and maintenance methods for the dental chair

The dental chair is the necessary dental equipment for the dentist. Sice the 1887, the first electric dental drill was born, the dental chair was improved sharply in the performance and intelligence. Recently, more and more new technology make the dental equipment more humanized.
Air, water and electricity are the three factors ofdental chair.So before the installation, the air and water pump line should be set before (better underground). It is better to install the first water filter in the water line, in case of affecting the life of water filter. The air pump should not be closed to the dental chair, because the air noise will affect the patient. If there a lot of dental equipment, it is suggested to use the center air supply, which will save the cost, reduce the breakdown and also ensure the air supply quality.
dentist office visit
Usually, the factory will install and test the equipment before the delivery. During the installation, the dentist should be on site, so that the dentist can solve some problems by themselves in the future.
The dental chair contain the integral type and separated type, but the integral type is widely used. It is included by the patient chair, dentist chair and curing machine. The patient chair has electric and manual. The electric patient chair contain three type, screw drive type, electrohydraulic type and belt driven type. Manually control is used the oil pressure to control the seat position. The curing machine contains the high speed hand piece, low speed hand piece, three spray gun, suction, auto cup filler, instrument tray, shadowless lamp, X ray viewer, scaler, curing light, spittoon and water, air and electricity control. The working theory is that the air control the water and electricity, then extract the teeth, insert teeth and fill teeth.
As the portable dental chair is the necessary equipment to the dentist, it is widely used and together with air, water and electricity. The daily maintenance will affect the life of equipment, so it is also very important to make the daily maintenance. Guangzhou Medsinglong has a strong after service for the dental chair, we have warranty commitment and technical support. In this way, we can save worry, save time and save money for the clients. Should there be any problems, please feel free to contact our technical engineer.
The first is the maintenance of the hand piece, which is the key part for the dental chair. During the use, the hand piece should be sterilized in the autoclave in case of cross-infection. To extend the life span of hand piece, please keep the daily maintenance of the hand piece. Before the first use, instill one or two drops of spindle oil in the hand piece. The hand piece should cleaned up usually, before the use, idle for 30 seconds in case of the oil into patient’s mouth. Although the oil is no harmful to the people, but if the resin have affected the operation face, the effect will be bad. During the daily use, the headstock should be cleaned by the clean lubricant. Every two weeks, the micro bearing should be cleaned once, the working pressure should be the normal around 0.2~0.25Mpa. If there is no water, the hand piece can not be idled,or the bearing will be damaged. The pins should be replaced after being used for a long time, or the the bearing will be damaged.
Note: after the use, the hand piece should be tore down in case of the patient out of the chair and damage the hand piece. The instrument tray should be lifted after the using, the water inside the pipe should be wiped out. The instrument tray can be onside the handrail to reduce the pressure. The equipment maintenance of the equipment is quite important to us, because the maintenance is come from our profit, so it is the best way to extend the use life.
The main maintenance of the dental chair for sale are air and water line. So the air, water and electricity should be shut up after the work, especially the air inside the spray gun should be wiped out, is case of the air pipe in the high pressure condition. Clean the filter timely according to the local water condition, wide out the air inside the filter and reduce the water inside the pressure reducing valve. Clean the attractor and salivary absorption. Especially pay attention to the water pressure and air pressure, the value should be the normal, in case of the filter and pipe burst. The operation light and the film viewer light should not the turned on or turned off frequently, or the bulb will be damaged.
Regarding the maintenance of the patient’s chair, check every drive disk assembly. The position of the drive disk assembly should be instilled the oil. Check the amount of oil oil quality in the tank of electro-hydraulic drive. If the oil is not enough or the oil quality is bad, please replace it immediately. adjust the tightness of the belt drive.
Related Posts
Cobalt chromium porcelain teeth which harm
The article comes from:The 6 installation and maintenance methods for the dental chair
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

The 6 installation and maintenance methods for the dental chair

The dental chair is the necessary dental equipment for the dentist. Sice the 1887, the first electric dental drill was born, the dental chair was improved sharply in the performance and intelligence. Recently, more and more new technology make the dental equipment more humanized.
Air, water and electricity are the three factors ofdental chair.So before the installation, the air and water pump line should be set before (better underground). It is better to install the first water filter in the water line, in case of affecting the life of water filter. The air pump should not be closed to the dental chair, because the air noise will affect the patient. If there a lot of dental equipment, it is suggested to use the center air supply, which will save the cost, reduce the breakdown and also ensure the air supply quality.
dentist office visit
Usually, the factory will install and test the equipment before the delivery. During the installation, the dentist should be on site, so that the dentist can solve some problems by themselves in the future.
The dental chair contain the integral type and separated type, but the integral type is widely used. It is included by the patient chair, dentist chair and curing machine. The patient chair has electric and manual. The electric patient chair contain three type, screw drive type, electrohydraulic type and belt driven type. Manually control is used the oil pressure to control the seat position. The curing machine contains the high speed hand piece, low speed hand piece, three spray gun, suction, auto cup filler, instrument tray, shadowless lamp, X ray viewer, scaler, curing light, spittoon and water, air and electricity control. The working theory is that the air control the water and electricity, then extract the teeth, insert teeth and fill teeth.
As the portable dental chair is the necessary equipment to the dentist, it is widely used and together with air, water and electricity. The daily maintenance will affect the life of equipment, so it is also very important to make the daily maintenance. Guangzhou Medsinglong has a strong after service for the dental chair, we have warranty commitment and technical support. In this way, we can save worry, save time and save money for the clients. Should there be any problems, please feel free to contact our technical engineer.
The first is the maintenance of the hand piece, which is the key part for the dental chair. During the use, the hand piece should be sterilized in the autoclave in case of cross-infection. To extend the life span of hand piece, please keep the daily maintenance of the hand piece. Before the first use, instill one or two drops of spindle oil in the hand piece. The hand piece should cleaned up usually, before the use, idle for 30 seconds in case of the oil into patient’s mouth. Although the oil is no harmful to the people, but if the resin have affected the operation face, the effect will be bad. During the daily use, the headstock should be cleaned by the clean lubricant. Every two weeks, the micro bearing should be cleaned once, the working pressure should be the normal around 0.2~0.25Mpa. If there is no water, the hand piece can not be idled,or the bearing will be damaged. The pins should be replaced after being used for a long time, or the the bearing will be damaged.
Note: after the use, the hand piece should be tore down in case of the patient out of the chair and damage the hand piece. The instrument tray should be lifted after the using, the water inside the pipe should be wiped out. The instrument tray can be onside the handrail to reduce the pressure. The equipment maintenance of the equipment is quite important to us, because the maintenance is come from our profit, so it is the best way to extend the use life.
The main maintenance of the dental chair for sale are air and water line. So the air, water and electricity should be shut up after the work, especially the air inside the spray gun should be wiped out, is case of the air pipe in the high pressure condition. Clean the filter timely according to the local water condition, wide out the air inside the filter and reduce the water inside the pressure reducing valve. Clean the attractor and salivary absorption. Especially pay attention to the water pressure and air pressure, the value should be the normal, in case of the filter and pipe burst. The operation light and the film viewer light should not the turned on or turned off frequently, or the bulb will be damaged.
Regarding the maintenance of the patient’s chair, check every drive disk assembly. The position of the drive disk assembly should be instilled the oil. Check the amount of oil oil quality in the tank of electro-hydraulic drive. If the oil is not enough or the oil quality is bad, please replace it immediately. adjust the tightness of the belt drive.
Related Posts
Cobalt chromium porcelain teeth which harm
The article comes from: The 6 installation and maintenance methods for the dental chair
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

Tuesday, March 10, 2015

6 major causes and treatment measures after dental tooth filling

How to remove pain after tooth fillings? Sometimes appeared toothache after root canal treatment after dental treatment.Root canal treatment is to remove the infections from root canal and fill it, isolated bacteria enter reinfection again,prevent apical inflammatory lesions or a process to produce the original lesion healing. Root canal therapy is the treatment of pulpitis, apical go far the most radical method of treatment, there are several common treatments:
Popeye The Dentist
1、Oral Diseases
This means oral diseases still exist before root canal therapy, there is no effective eradication therapy. Bacterial have not been fully removed in the treatment due to doctor's improper operation. this will cause the bacterials spread and cause sharp pain.
2、Improper operation
Some of pain are occured because of toot canal treatment.example:after root canal therapy in the treatment of the root canal of varying lengths, with real teeth tissue site frequent friction, etc., which led to some inflammation,and also may cause bacterials and result in re-treatment because of failure.
3、material filling
The root canal filler now more and more, for different body characteristics, the effect produced by each material is not the same. Before root canal treatment, the doctor should first conduct a comprehensive examination of the patient, to keep abreast of some patients, such as allergic reactions. In this case, the choice of root canal filling material,you can choose to avoid patients' allergic to the material, and it can not only reduce pain,but also improve the success rate treatment.
4、Treatment is needed in case of pulp inactivation,the pulp inactivation (commonly known as the nerve-kill), The drug or the next day because the drug effect may appear a toothache on the day after the closure inactivate, but the pain will not be very severe and do not last very long time.
5、Stimulation of disinfection drug , because the process of preparation of dental shaped hole or sterilization of drug-induced stimulation of the pulp may occur short-term pain of hot and cold stimuli, such cases do not need special treatment, and can recover by itself after 1-2 days.
6、Deep cavities with too thin a cushioning materia can not cut off conduction amalgam of hot and cold stimulation, and the emergence of symptoms of cold and heat pain,this requires thicker base materials before filling. The pain or spontaneous pain in later stage after treatment may be caused by the filled material to stimulate certain chemicals or apical pulp tissue,ormay be because of incomplete inactivation pulp. The reason for the long-term pain is often complicated by secondary caries pulpitis. It should be appease or other endodontic treated depends on specific circumstances. Mostly filling material is too high if there is recent painful bite, it will recover after several days adjustments.

In short, in addition to temporary pains told by doctor (eg pulp inactivation), the situation after the other various fillings toothache should go to hospital for treatment, in order to identify the causes and timely treatment. Guangzhou provide a wide services for after-sales service,warranty, technical support.pls contact us at cindy@medicalequipment- msl.com if there is any technical question.

What to do if pain after tooth fillings? Anti-inflammatory drugs or painkillers can ease the pain after root canal treatment. The patient should inform physician if The emergence of swell. To remind that root canal treatment must be to a regular hospital for treatment, so to avoid reducing toothache after root canal treatment.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,X-ray machine,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.

Related Posts
Concern the oral health,which is the best way to cure the missing teeth.
The article comes from:6 major causes and treatment measures after dental tooth filling
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

6 major causes and treatment measures after dental tooth filling

How to remove pain after tooth fillings? Sometimes appeared toothache after root canal treatment after dental treatment.Root canal treatment is to remove the infections from root canal and fill it, isolated bacteria enter reinfection again,prevent apical inflammatory lesions or a process to produce the original lesion healing. Root canal therapy is the treatment of pulpitis, apical go far the most radical method of treatment, there are several common treatments:
Popeye The Dentist
1、Oral Diseases
This means oral diseases still exist before root canal therapy, there is no effective eradication therapy. Bacterial have not been fully removed in the treatment due to doctor's improper operation. this will cause the bacterials spread and cause sharp pain.
2、Improper operation
Some of pain are occured because of toot canal treatment.example:after root canal therapy in the treatment of the root canal of varying lengths, with real teeth tissue site frequent friction, etc., which led to some inflammation,and also may cause bacterials and result in re-treatment because of failure.
3、material filling
The root canal filler now more and more, for different body characteristics, the effect produced by each material is not the same. Before root canal treatment, the doctor should first conduct a comprehensive examination of the patient, to keep abreast of some patients, such as allergic reactions. In this case, the choice of root canal filling material,you can choose to avoid patients' allergic to the material, and it can not only reduce pain,but also improve the success rate treatment.
4、Treatment is needed in case of pulp inactivation,the pulp inactivation (commonly known as the nerve-kill), The drug or the next day because the drug effect may appear a toothache on the day after the closure inactivate, but the pain will not be very severe and do not last very long time.
5、Stimulation of disinfection drug , because the process of preparation of dental shaped hole or sterilization of drug-induced stimulation of the pulp may occur short-term pain of hot and cold stimuli, such cases do not need special treatment, and can recover by itself after 1-2 days.
6、Deep cavities with too thin a cushioning materia can not cut off conduction amalgam of hot and cold stimulation, and the emergence of symptoms of cold and heat pain,this requires thicker base materials before filling. The pain or spontaneous pain in later stage after treatment may be caused by the filled material to stimulate certain chemicals or apical pulp tissue,ormay be because of incomplete inactivation pulp. The reason for the long-term pain is often complicated by secondary caries pulpitis. It should be appease or other endodontic treated depends on specific circumstances. Mostly filling material is too high if there is recent painful bite, it will recover after several days adjustments.

In short, in addition to temporary pains told by doctor (eg pulp inactivation), the situation after the other various fillings toothache should go to hospital for treatment, in order to identify the causes and timely treatment. Guangzhou provide a wide services for after-sales service,warranty, technical support.pls contact us at cindy@medicalequipment- msl.com if there is any technical question.

What to do if pain after tooth fillings? Anti-inflammatory drugs or painkillers can ease the pain after root canal treatment. The patient should inform physician if The emergence of swell. To remind that root canal treatment must be to a regular hospital for treatment, so to avoid reducing toothache after root canal treatment.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,X-ray machine,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.

Related Posts
Concern the oral health,which is the best way to cure the missing teeth.
The article comes from:6 major causes and treatment measures after dental tooth filling
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

Tuesday, March 3, 2015

10 methods to judge whether the ultrasound probe working regularly or not

The cheap ultrasound machines is one of the costly and common used in hospital. Thus, it's very common that the ultrasound probe breaks down for various reasons. Here technicians in MEDSINGLONG GLOBAL GROUP CO.,LTD tell you how to analyze the malfunction in it.
MSL probe for sale
Firstly, appearance (whether there's any breakage)
1. Damage on acoustical lens will result in coupling agent into the probe, which affects the detection range or even no images.
2. Bubbles on the acoustical lens will lead to this situation, we need to press the lens to get images.
3. Acoustic lens is convergence or divergence of sound wave acoustic components, the probe can't function when lens is missing.

Secondly, there's dark stripe in ultrasound display area
No signal input or output in the probe will lead to dark stripe, reasons may be:
4. One quartz vibrator inside the probe breaks down
5. The cables which sends signal breaks down
6. Copper lines on the signal board break down
7. The chip inside the signal board is pseudo soldering or burns out

Thirdly, Image blurring
8. Normal wear and tear of the probe itself.
9. Poor operational environment. Temperature, humidity, corrosive gas and dust in the air and other factors may cause instrument malfunction.
10. Probe shielded wire and ground wire no grounding or broken lead to interference. Ultrasound probe cable is adopted by the high quality requirements of high multi-fiber shielded cable. Due to the frequent use of probe, the cable is easy to damage, which results in blurring images.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,cheap x ray machines,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,portable fluoroscopy machine,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.

Related Posts
What is USG?
What is 3D and 4D ultrasound definition?
The article comes from:10 methods to judge whether the ultrasound probe working regularly or not
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok

10 methods to judge whether the ultrasound probe working regularly or not

The cheap ultrasound machines is one of the costly and common used in hospital. Thus, it's very common that the ultrasound probe breaks down for various reasons. Here technicians in MEDSINGLONG GLOBAL GROUP CO.,LTD tell you how to analyze the malfunction in it.
MSL probe for sale
Firstly, appearance (whether there's any breakage)
1. Damage on acoustical lens will result in coupling agent into the probe, which affects the detection range or even no images.
2. Bubbles on the acoustical lens will lead to this situation, we need to press the lens to get images.
3. Acoustic lens is convergence or divergence of sound wave acoustic components, the probe can't function when lens is missing.

Secondly, there's dark stripe in ultrasound display area
No signal input or output in the probe will lead to dark stripe, reasons may be:
4. One quartz vibrator inside the probe breaks down
5. The cables which sends signal breaks down
6. Copper lines on the signal board break down
7. The chip inside the signal board is pseudo soldering or burns out

Thirdly, Image blurring
8. Normal wear and tear of the probe itself.
9. Poor operational environment. Temperature, humidity, corrosive gas and dust in the air and other factors may cause instrument malfunction.
10. Probe shielded wire and ground wire no grounding or broken lead to interference. Ultrasound probe cable is adopted by the high quality requirements of high multi-fiber shielded cable. Due to the frequent use of probe, the cable is easy to damage, which results in blurring images.

MEDSINGLONG GLOBAL GROUP CO.,LTD are able to offer a range of medical products,such as Ultrasound machine,cheap x ray machines,Dental equipment,Autoclaves,ECG,Blood analyzer,Biochemical analyzer,Vet equipment,portable fluoroscopy machine ,Radiation protection equipment and so on.Whether the hospital or clinic,or for personal use,you can find your own favorite products.Our mission is;No the best,only better!We are ready to serve you.

Related Posts
What is USG?
What is 3D and 4D ultrasound definition?
The article comes from:10 methods to judge whether the ultrasound probe working regularly or not
More about my team,you can click the video:https://www.youtube.com/watch?v=DzWaeE7MEok